foldable intraocular lens with a optic acrysof iq sn60wf Search Results


90
alcon inc acrysof sn60wf implant
Acrysof Sn60wf Implant, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/foldable+intraocular+lens+with+a+optic+acrysof+iq+sn60wf/pm28951074-2-10-20?v=alcon+inc
Average 90 stars, based on 1 article reviews
acrysof sn60wf implant - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
alcon inc acrysof iq
Acrysof Iq, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/foldable+intraocular+lens+with+a+optic+acrysof+iq+sn60wf/pmc11343009-39-1-3?v=alcon+inc
Average 90 stars, based on 1 article reviews
acrysof iq - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
alcon inc multifocal aspheric iol acrysof restor sn6ad1
Multifocal Aspheric Iol Acrysof Restor Sn6ad1, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/foldable+intraocular+lens+with+a+optic+acrysof+iq+sn60wf/pmc03443835-64-44-50?v=alcon+inc
Average 90 stars, based on 1 article reviews
multifocal aspheric iol acrysof restor sn6ad1 - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
alcon inc monarch injector and c-cartridge system
Monarch Injector And C Cartridge System, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/foldable+intraocular+lens+with+a+optic+acrysof+iq+sn60wf/pmc03958628-30-36-38?v=alcon+inc
Average 90 stars, based on 1 article reviews
monarch injector and c-cartridge system - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Medicel AG viscoject injector and viscoglide cartridge system
Viscoject Injector And Viscoglide Cartridge System, supplied by Medicel AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/foldable+intraocular+lens+with+a+optic+acrysof+iq+sn60wf/pmc03958628-30-14-17?v=Medicel+AG
Average 90 stars, based on 1 article reviews
viscoject injector and viscoglide cartridge system - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
alcon inc d-cartridge
D Cartridge, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/foldable+intraocular+lens+with+a+optic+acrysof+iq+sn60wf/pmc04687189-43-27-28?v=alcon+inc
Average 90 stars, based on 1 article reviews
d-cartridge - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
alcon inc acrysof iols
The summary of major original studies on glistenings
Acrysof Iols, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/foldable+intraocular+lens+with+a+optic+acrysof+iq+sn60wf/pmc07729367-443-395-397?v=alcon+inc
Average 90 stars, based on 1 article reviews
acrysof iols - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Carl Zeiss hydrophilic acrylic iol (ct asphina ® 603p, carl meditec
Comparison of demographic and clinical characteristics of eyes with and without negative dysphotopsia
Hydrophilic Acrylic Iol (Ct Asphina ® 603p, Carl Meditec, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/foldable+intraocular+lens+with+a+optic+acrysof+iq+sn60wf/pmc08374810-64-55-62?v=Carl+Zeiss
Average 90 stars, based on 1 article reviews
hydrophilic acrylic iol (ct asphina ® 603p, carl meditec - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Carl Zeiss ct lucia 601py
Comparison of demographic and clinical characteristics of eyes with and without negative dysphotopsia
Ct Lucia 601py, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/foldable+intraocular+lens+with+a+optic+acrysof+iq+sn60wf/10__3928_slash_1081597x___20230605___02-59-60-138?v=Carl+Zeiss
Average 90 stars, based on 1 article reviews
ct lucia 601py - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

Image Search Results


The summary of major original studies on glistenings

Journal: Annals of Translational Medicine

Article Title: A narrative review of intraocular lens opacifications: update 2020

doi: 10.21037/atm-20-4207

Figure Lengend Snippet: The summary of major original studies on glistenings

Article Snippet: A high amount of glistenings developed in most SN60WF IOLs, while only few ZCB00 IOLs displayed a low degree of glistenings Chang et al. ( 83 ) 80 patients: 40 AcrySof SA60AT (1-piece IOL group); 40 a Sensar AR40e (3-piece IOL group) 5 to 7 years postoperatively, retroillumination images were obtained and the PCO area and severity were evaluated using computer software There were no significant differences in PCO between the 2 groups High-contrast (100%) and low-contrast (2.5%) CDVA were measured The 3-piece IOL group had significantly fewer glistenings (P<0.001) Scheimpflug images were obtained to evaluate glistenings, which were quantified objectively by digital image analysis using computer software There was correlation between the subjective grading of glistenings and objective computer-processed image grading The glistenings were not correlated with IOL power, CDVA, or CS Thomes et al. ( 82 ) AcrySof Natural IOLs Model SB30 AL (n=100) manufactured in 2003 Glistenings were induced in vitro Glistenings were present in all lenses after the accelerated microvacuole test method AcrySof Natural IQ Model SN60 WF IOLs (n=270) manufactured in 2012 Image analysis program was used to evaluate glistenings The mean microvacuole density for IOLs manufactured in 2003 was 315.7 microvacuoles per square millimeter (MVs/mm 2 ) with a glistening severity less than 100 MVs/mm 2 in 1.0% of the IOLs The mean microvacuole density for IOLs manufactured in 2012 was 39.9 MVs/mm 2 with a glistening severity less than 100 MVs/mm 2 in 95.2% of the IOLs Laboratory-induced microvacuole density was significantly lower in IOLs manufactured in 2012 (mean 39.9 MVs/mm 2 ) relative to IOLs manufactured in 2003 (mean 315.7 MVs/mm 2 ) as indicated by the Wilcoxon test of significance (P<0.0005) Miyata et al. ( 35 ) 24 eyes received AcrySof SN60WF IOL before manufacturing improvement Light scattering on the anterior IOL surface was examined up to 3 years postoperatively using an EAS-1000 anterior segment analyzer After the improvement, the IOLs showed no increase in surface light scattering up to 2 years, a significant increase was found at 3 years (P<0.001) 27 eyes received AcrySof SN60WF IOL after improvement The CDVA and CS under photopic and mesopic conditions were also examined 3 years postoperatively The light scattering with the improved IOL was significantly reduced at all observations (P<0.048) No difference was found in the CDVA and CS van der Mooren et al. ( 84 ) 5 AcrySof IOLs (Alcon Laboratories Inc, Forth Worth, Texas, USA) Glistenings were induced in vitro .

Techniques: Control, Transmission Assay, Spectrophotometry, In Vitro, Derivative Assay, Incubation, Microscopy, Imaging, Software, Light Microscopy, Standard Deviation

The summary of risk factors for IOL glistenings and calcifications

Journal: Annals of Translational Medicine

Article Title: A narrative review of intraocular lens opacifications: update 2020

doi: 10.21037/atm-20-4207

Figure Lengend Snippet: The summary of risk factors for IOL glistenings and calcifications

Article Snippet: A high amount of glistenings developed in most SN60WF IOLs, while only few ZCB00 IOLs displayed a low degree of glistenings Chang et al. ( 83 ) 80 patients: 40 AcrySof SA60AT (1-piece IOL group); 40 a Sensar AR40e (3-piece IOL group) 5 to 7 years postoperatively, retroillumination images were obtained and the PCO area and severity were evaluated using computer software There were no significant differences in PCO between the 2 groups High-contrast (100%) and low-contrast (2.5%) CDVA were measured The 3-piece IOL group had significantly fewer glistenings (P<0.001) Scheimpflug images were obtained to evaluate glistenings, which were quantified objectively by digital image analysis using computer software There was correlation between the subjective grading of glistenings and objective computer-processed image grading The glistenings were not correlated with IOL power, CDVA, or CS Thomes et al. ( 82 ) AcrySof Natural IOLs Model SB30 AL (n=100) manufactured in 2003 Glistenings were induced in vitro Glistenings were present in all lenses after the accelerated microvacuole test method AcrySof Natural IQ Model SN60 WF IOLs (n=270) manufactured in 2012 Image analysis program was used to evaluate glistenings The mean microvacuole density for IOLs manufactured in 2003 was 315.7 microvacuoles per square millimeter (MVs/mm 2 ) with a glistening severity less than 100 MVs/mm 2 in 1.0% of the IOLs The mean microvacuole density for IOLs manufactured in 2012 was 39.9 MVs/mm 2 with a glistening severity less than 100 MVs/mm 2 in 95.2% of the IOLs Laboratory-induced microvacuole density was significantly lower in IOLs manufactured in 2012 (mean 39.9 MVs/mm 2 ) relative to IOLs manufactured in 2003 (mean 315.7 MVs/mm 2 ) as indicated by the Wilcoxon test of significance (P<0.0005) Miyata et al. ( 35 ) 24 eyes received AcrySof SN60WF IOL before manufacturing improvement Light scattering on the anterior IOL surface was examined up to 3 years postoperatively using an EAS-1000 anterior segment analyzer After the improvement, the IOLs showed no increase in surface light scattering up to 2 years, a significant increase was found at 3 years (P<0.001) 27 eyes received AcrySof SN60WF IOL after improvement The CDVA and CS under photopic and mesopic conditions were also examined 3 years postoperatively The light scattering with the improved IOL was significantly reduced at all observations (P<0.048) No difference was found in the CDVA and CS van der Mooren et al. ( 84 ) 5 AcrySof IOLs (Alcon Laboratories Inc, Forth Worth, Texas, USA) Glistenings were induced in vitro .

Techniques: Medications, Injection

The summary of studies evaluating the impact of IOL glistenings and calcifications on visual quality

Journal: Annals of Translational Medicine

Article Title: A narrative review of intraocular lens opacifications: update 2020

doi: 10.21037/atm-20-4207

Figure Lengend Snippet: The summary of studies evaluating the impact of IOL glistenings and calcifications on visual quality

Article Snippet: A high amount of glistenings developed in most SN60WF IOLs, while only few ZCB00 IOLs displayed a low degree of glistenings Chang et al. ( 83 ) 80 patients: 40 AcrySof SA60AT (1-piece IOL group); 40 a Sensar AR40e (3-piece IOL group) 5 to 7 years postoperatively, retroillumination images were obtained and the PCO area and severity were evaluated using computer software There were no significant differences in PCO between the 2 groups High-contrast (100%) and low-contrast (2.5%) CDVA were measured The 3-piece IOL group had significantly fewer glistenings (P<0.001) Scheimpflug images were obtained to evaluate glistenings, which were quantified objectively by digital image analysis using computer software There was correlation between the subjective grading of glistenings and objective computer-processed image grading The glistenings were not correlated with IOL power, CDVA, or CS Thomes et al. ( 82 ) AcrySof Natural IOLs Model SB30 AL (n=100) manufactured in 2003 Glistenings were induced in vitro Glistenings were present in all lenses after the accelerated microvacuole test method AcrySof Natural IQ Model SN60 WF IOLs (n=270) manufactured in 2012 Image analysis program was used to evaluate glistenings The mean microvacuole density for IOLs manufactured in 2003 was 315.7 microvacuoles per square millimeter (MVs/mm 2 ) with a glistening severity less than 100 MVs/mm 2 in 1.0% of the IOLs The mean microvacuole density for IOLs manufactured in 2012 was 39.9 MVs/mm 2 with a glistening severity less than 100 MVs/mm 2 in 95.2% of the IOLs Laboratory-induced microvacuole density was significantly lower in IOLs manufactured in 2012 (mean 39.9 MVs/mm 2 ) relative to IOLs manufactured in 2003 (mean 315.7 MVs/mm 2 ) as indicated by the Wilcoxon test of significance (P<0.0005) Miyata et al. ( 35 ) 24 eyes received AcrySof SN60WF IOL before manufacturing improvement Light scattering on the anterior IOL surface was examined up to 3 years postoperatively using an EAS-1000 anterior segment analyzer After the improvement, the IOLs showed no increase in surface light scattering up to 2 years, a significant increase was found at 3 years (P<0.001) 27 eyes received AcrySof SN60WF IOL after improvement The CDVA and CS under photopic and mesopic conditions were also examined 3 years postoperatively The light scattering with the improved IOL was significantly reduced at all observations (P<0.048) No difference was found in the CDVA and CS van der Mooren et al. ( 84 ) 5 AcrySof IOLs (Alcon Laboratories Inc, Forth Worth, Texas, USA) Glistenings were induced in vitro .

Techniques: Produced, Control

Comparison of demographic and clinical characteristics of eyes with and without negative dysphotopsia

Journal: Indian Journal of Ophthalmology

Article Title: Incidence and causes of negative dysphotopsia after uncomplicated cataract surgery – A randomized clinical trial

doi: 10.4103/ijo.IJO_3751_20

Figure Lengend Snippet: Comparison of demographic and clinical characteristics of eyes with and without negative dysphotopsia

Article Snippet: All consenting patients were first randomized at the time of enrollment into two treatment groups based on the type of IOL to be placed: a hydrophobic acrylic IOL (Alcon Acrysof ® SN60WF) made of high index material (refractive index = 1.55), a 6-mm optic with a square edge optic design and C-loop haptics and a hydrophilic acrylic IOL (CT Asphina ® 603P, Carl Zeiss Meditec) with a 6-mm optic, square-edged optic design, refractive index of 1.46 and plate haptics.

Techniques:

Comparison in clinical characteristics between two types of  IOL  and in between eyes that had and did not have wound hydration

Journal: Indian Journal of Ophthalmology

Article Title: Incidence and causes of negative dysphotopsia after uncomplicated cataract surgery – A randomized clinical trial

doi: 10.4103/ijo.IJO_3751_20

Figure Lengend Snippet: Comparison in clinical characteristics between two types of IOL and in between eyes that had and did not have wound hydration

Article Snippet: All consenting patients were first randomized at the time of enrollment into two treatment groups based on the type of IOL to be placed: a hydrophobic acrylic IOL (Alcon Acrysof ® SN60WF) made of high index material (refractive index = 1.55), a 6-mm optic with a square edge optic design and C-loop haptics and a hydrophilic acrylic IOL (CT Asphina ® 603P, Carl Zeiss Meditec) with a 6-mm optic, square-edged optic design, refractive index of 1.46 and plate haptics.

Techniques:

Comparison in clinical characteristics between four groups with combinations of  IOL  type and hydration

Journal: Indian Journal of Ophthalmology

Article Title: Incidence and causes of negative dysphotopsia after uncomplicated cataract surgery – A randomized clinical trial

doi: 10.4103/ijo.IJO_3751_20

Figure Lengend Snippet: Comparison in clinical characteristics between four groups with combinations of IOL type and hydration

Article Snippet: All consenting patients were first randomized at the time of enrollment into two treatment groups based on the type of IOL to be placed: a hydrophobic acrylic IOL (Alcon Acrysof ® SN60WF) made of high index material (refractive index = 1.55), a 6-mm optic with a square edge optic design and C-loop haptics and a hydrophilic acrylic IOL (CT Asphina ® 603P, Carl Zeiss Meditec) with a 6-mm optic, square-edged optic design, refractive index of 1.46 and plate haptics.

Techniques:

Univariate and multivariable logistic regression analysis for factors associated with occurrence of negative dysphotopsia in our cohort ( n =29 eyes)

Journal: Indian Journal of Ophthalmology

Article Title: Incidence and causes of negative dysphotopsia after uncomplicated cataract surgery – A randomized clinical trial

doi: 10.4103/ijo.IJO_3751_20

Figure Lengend Snippet: Univariate and multivariable logistic regression analysis for factors associated with occurrence of negative dysphotopsia in our cohort ( n =29 eyes)

Article Snippet: All consenting patients were first randomized at the time of enrollment into two treatment groups based on the type of IOL to be placed: a hydrophobic acrylic IOL (Alcon Acrysof ® SN60WF) made of high index material (refractive index = 1.55), a 6-mm optic with a square edge optic design and C-loop haptics and a hydrophilic acrylic IOL (CT Asphina ® 603P, Carl Zeiss Meditec) with a 6-mm optic, square-edged optic design, refractive index of 1.46 and plate haptics.

Techniques: